WENZHOU AOYING ELECTRIC CO.,LTD

Products >> Photovoltaic system protection >> Solar PV Fuse

  • 1500V 20A AFPV-32L 10*85mm DC Fuse
1500V 20A AFPV-32L 10*85mm DC Fuse

1500V 20A AFPV-32L 10*85mm DC Fuse

 1500V 20A AFPV-32L 10*85mm DC Fuse


Description

Fuses are simple, reliable, and stable in nature. With their simple construction, fuses are neither fragile nor prone to wearing down over time. Photovoltaic fuses have a structure specially designed for the electrical characteristics of photovoltaic power generation systems, providing all necessary overload current and short-circuit characteristics required to protect photovoltaic modules.


In addition to the above protection capabilities, AOYWELL  new generation of photovoltaic fuses also have a variety of world-wide installation methods, compatible design in line with national electrical standards, and full range of protection. AOYWELL’s team of application engineers and sales engineers are dedicated to protecting your renewable energy system, from R&D to delivery.


Features & Benefits

High voltage rating up to 1500V

Excellent performance at temperature extremes

Worldwide standard certification

Compact fuse size

Low temperature rise


Application

Photovoltaic applications

PV string/array level protection

1500V string inverter

1500V combiner box


Specification

Product Series

AFPV1085 AFPV1485 AFPV2258

Ratings


Voltage

Up to 1500Vdc

Current

6A, 10A ,12A 15A 16A 20A 32A 40A 50A 63A 80A

Breaking Capacity

50kA

Time constant

1-3ms

Operating class

IEC60269-6 gPV class UL

UL® Listed to 248-19, Guide JFGA,

Country of Origin

China


Dimension

CFPV1085

AFPV10*85


CFPV1485

AFPV14*85


CFPV2258

                                                                                                                                                    AFPV22*58

 Factory & Workshop

FAQ

Q: What is the pre-arcing time of a fuse?

A: Interval of time between the beginning of a current large enough to cause a break in the fuse_element(s) and the instant when an arc is initiatedinterval of time between the beginning of a current large enough to cause a break in the fuseelement(s) and the instant when an arc is initiate.


Q: What is the total clearing time of a fuse?

A: Sum of the pre-arcing time and the arcing time.


Q: What is the power dissipation (in a fuse-link) of a fuse?

A: Power released in a fuse-link carrying a stated value of electric current under prescribed conditions of use and behaviour.